On receipt of the No Objection Certificate, the applicant shall submit an application for approval of the plan of the building to be constructed on the approved site to the Licensing Authority. Such application shall be accompanied by,-
(i) a copy of the no objection certificate granted under rule 27;
(ii) a copy of the approved site plan;
(iii) complete plan, elevation and sections in quadruplicate in original printed on tracing film and also in digital format with four prints of the premises and of all erections and buildings thereon drawn correctly to a scale of not less than 1:100 on prints taken out of any of the standard size tracings and showing clearly,-
(a) all dimensions in millimeters and materials of construction indicating the different materials in distinguishing colours and giving in figures dimensions the width and depth of walls, beams, scantlings and trusses;
(b) the width of all staircases and the number of steps in each flight with the rise and tread of steps the clear width of corridors, passages, openings, aisles and gangways as well as the height and constructions of all galleries, tiers, balconies and stages; and fire resistance rate of staircases shall be one hour. No gas pipeline or electrical lines shall be attached to it. Anti slippery nosing shall be installed for the steps. One metre height of handrail be provided.
(c) the sizes of all doors, windows and ventilators indicating their construction and the way in which they open and the proposed system of ventilation;
(d) the proposed seating arrangement;
(e) the plinth area of each building in square meters separately for ground floor and upper floors and in tiers, galleries or balconies;
(f) staircases;
(g) water closets and urinals;
(h) levels at the different parts of the building in plans and sections; and
(i) details and positions of projectors, screen, sound box and other plants and equipment;
(iv) detailed specifications of the works in triplicate to be executed, sufficiently describing the material to be employed and the mode of construction to be adopted with calculations, in triplicate showing the loads coming and stresses occurring in all foundations, piers, columns, stanchions, lintels, beams, slabs, joists and trusses, such calculations being certified to be correct by a graduate engineer or a design engineer or a design practitioner or a qualified architect