Transforming and converting machinery with the controlling switches and circuit breakers shall be placed in a place adequately ventilated to outside air, properly lighted and accessible to the management and shall be used for no other purpose:
(1) Main switch with overload and earth leakage protection shall be provided in the main switchboard for the control of entire electrical installation. All circuits shall be efficiently protected by circuit breakers of suitable capacity placed in positions easily accessible to the staff and in places where they are not likely to obstruct any passage or exits.
(2) The switch boards if they are accessible to the public and if they are in the ticket booths, shall be provided with proper lock-up cases with glass or metal front and the glass (unless of adequate thickness) shall be protected with a wire guard or alternatively boxes with lids and sides rendered fire proof by using suitable fire resistant material.
(3) All switches and circuit breakers of suitable capacity shall be so marked as to show clearly which circuit or lamps they control.
(1) Such number and type of accumulators or automatic DC lights as may be approved by the Electrical Inspector shall be installed to illuminate the auditorium during an emergency or failure of power.
(2) The accumulators shall be placed in a room adequately ventilated to the outside air and this room shall be of fire-proof construction with fire resisting doors and shall not be used for any other purpose.
(1) In this chapter unless the context otherwise requires, “Semi-permanent Cinema Building” means a building other than the building licensed for touring cinema, temporary cinema, drive-in-cinema, permanent Cinema or multiplex.
(2) Application of rules.— The rules in this Chapter and the rules and sub-rules specified below shall mutatis mutandis be applicable to semi permanent cinema buildings, namely:-
(a) rule 2 except sub-rule (21), (23) and (28).
(b) rule 3, 4, 5, 6, 7 to 23.
(c) rule 24, 25.
(d) rule 26, sub rules (1)(a)(i)(ii)(iii)(v)(vii), (b),(c), (d), (e), (f), (g), (h), (j), (k), (2) (i)(ii), (3) and (4).
(e) rule 27, 28, 30, 31, 32 and 33.
(f) rule 34 (1)(a)(b), (2) rules 43 to 56 except 44, 45, 47 and 56 (2) rules 3, 48, 51(9), 57 to 73, 77(5) and 82}
(g) rule 35
(h) rule 36, 37, 40 and 41.
(i) rule 42 sub rules (1), (2), (5), (7), (8), (9), (10) and (12) to (18).
(j) rules 43, 46, 48, 49 to 52, 53, 54, and 55.
(k) rules 57 to 73, 74 to 76, 77 to 84 and 85-87.
No Objection Certificates for the location of semi-permanent cinemas shall not be granted,-
(a) in towns and cities the population of which is 50,000 or above;
(b) in a place where the total number of existing permanent cinemas and semi permanent cinemas exceed the number of permanent cinemas that can be licensed at such place in accordance with sub-rule (2) of rule 26.
(1) A person who intends to construct a semi-permanent cinema building shall make an application to the Licensing Authority in form ‘A’. He shall also put up a notice in form 'B' in this behalf on a board on the proposed site or the building to be converted as the case may be, in such a position that it can be plainly seen from the public thoroughfare. Such notice shall be in the regional language and in English. The notice on the Board shall be on display until the application for licence is decided by the Licensing Authority. The Board shall be at least 1.25m x 1.00 m in size and the notice shall be in bold and clearly legible letters.
(2) The Application shall be accompanied by.__
(i) an extract in six copies with one original plan printed on tracing film and also in digital format, of a town map drawn correctly to scale and six prints or copies of the same map shall be provided clearly indicating the surrounding roads and buildings which exist upto a distance of 500 meters from the proposed site, the distance of all educational institutions, hospitals, places of worship or other places of public importance from the said site;
(ii) The site plan in original printed on tracing film and also in digital format with six prints drawn correctly to scale of not less than 1:500 indicating therein the block levels, showing position of the semi-permanent cinema and its premises in relation to any adjacent buildings, out-houses and other structures, sub-ways, roads, passages, wells, cisterns, hydrants , if any, drains, water sewer and gas mains, underground cables, overhead high and extra high voltage lines, telegraph and telephone lines, high flood marks of nearby river or nalas, maximum water level of adjacent reservoirs, tanks, water level of adjacent wells, if any in the rainy season within the site and giving the size of the site as well as the proposed built and open areas in square meters together with number of seats to be accommodated; and
(iii) The treasury challan for having credited the fees as specified by the Government from time to time for the grant of No Objection Certificate.
(1) The Licensing Authority or an officer authorized by him; or any Police officer not below the rank of a Station House Officer; or any Fire Officer not below the rank of a Fire Station Officer of Karnataka State Fire and Emergency Services; or any Health Officer not below the rank of a Taluk Health Officer; or any officer not below the rank of Electrical Inspector; or any Executive Magistrate having jurisdiction over the area; or The Executive Engineer, Public Works, Ports and inland transport Department or any person authorized by him, may enter, at anytime, the place licensed or proposed to be licensed under the Act and the Rules for the purpose of satisfying himself that the provisions of the Act and the rules made thereunder, are being complied with by the licensee.
(2) The licensee shall, on demand by any of the Officers referred to in sub–rule (1) produce the license, the plan and the description attached thereto and the said Officers shall communicate to the licensee, through the Licensing Authority, from time to time or as occasion arises their orders in regard to the safety or convenience of the public or for the preservation and maintenance of law, order, peace and public decency. The Licensing Authority may if the circumstances so require after notice to the licensee direct him to provide additional safeguards and the licensee shall comply with such direction failing which the licence shall be liable to be cancelled or suspended.
(3) During the periods of epidemics and similar health hazards to public or in case of disasters, in general, the Licensing Authority in consultation with the District Health Officer, Taluka Health Officer or the Health Officer of the Municipality, if any, may, if so advised, direct by a special notice,-
(a) complete closure if the need arises;
(b) a reduction in the scale of accommodation prescribed in Rule 49;
(c) The periodical disinfection of premises which may include spraying and fumigation; and
(d) The adoption of such other measures for better ventilation as may be specified in the notice;
and the licensee shall comply forthwith any such direction and in case of failure to do so, the license granted to him shall be liable for suspension or cancellation.
(1) The Licensing Authority shall on receipt of an application under rule 116, notify, at the cost of the applicant, to the public of such intention by publication in two local newspapers (one in Kannada and one in English) having wide circulation in the area inviting objections. Such notice shall be in Form ‘C’ and the period within which the objections shall be sent to the Licensing Authority shall be fifteen days from the date of such publication. The Licensing Authority shall simultaneously forward copies of the application, with its accompaniments furnished by the applicant to Town Planning Officer in City Corporation /Urban Development Authority/ Planning Authority/Assistant Director, Town and Country Planning of the district as the case may be, District Health and Family Welfare Officer, Executive Engineer, Public Works, Ports and inland transport Department of the district and the Superintendent of Police of the district/ Commissioner of Police of the city/ District Fire Officer of Fire and Emergency Services of the district / Electrical Inspector of the District or area for the purpose of ascertaining their views regarding suitability or otherwise of the proposed site for the location of a semi-permanent cinema.
(2) The Licensing Authority shall, as early as possible and in any case within a period not exceeding thirty days after the expiry of period specified in sub-rule (1), take a decision regarding the suitability or otherwise of the proposed site for the location of the semi-permanent cinema. The different authorities mentioned in sub-rule (1) shall furnish their views to the Licensing Authority as early as possible and in any case within a period of thirty days after the expiry of period mentioned in sub-rule (1). If no views are furnished by the authorities specified within the specified period, the Licensing Authority shall presume that there is no objection to the grant of No Objection Certificate.
(3) The Licensing Authority shall, before taking a decision regarding the suitability or otherwise of the site for the location of the semi-permanent cinema take into consideration the opinion of the different authorities mentioned in sub rule (1) and objections, if any received in response to the publication under sub-rule (1).
(1) No Objection Certificate shall not be granted under this chapter in respect of any cinema unless,-
(a) the cinema site is of a minimum area of,-
(i) If the total number of seats in the proposed cinema building is Four hundred or less, Nine hundred square meters with one side of not less than Eighteen meters abutting the road;
(ii) If the total number of seats in the proposed cinema building is Six hundred or less, One thousand three hundred and fifty square meters with one side of not less than Eighteen meters abutting the road;
(iii) If the total number of seats in the proposed cinema building is Eight hundred or less, One thousand eight hundred square meters with one side of not less than Thirty meters abutting the road in cases where the theatre does not have a balcony seating arrangement;
(iv) If the total number of seats in the proposed cinema building is One thousand or less, Two thousand two hundred and fifty square meters with one side of not less than thirty meters abutting the road; in cases where the theatre does not have a balcony seating arrangement;
(v) If the total number of seats in the proposed cinema building is One thousand or less, One thousand five hundred square meters with one side of not less than twenty meters abutting the road; in cases theatre has a balcony seating arrangement;
(b) (i) The cinema site is situated in permissible zones of land use earmarked in master plan prepared for an area by the competent authority under Karnataka Town and Country Planning Act:
Provided that where master plans have not been prepared existing predominantly commercial areas shall be taken into consideration.
(ii) In rural areas in the absence of approved master plans a cinema theatre or multiplex may be permitted by the licensing authority, if the conditions are fulfilled regarding road width and all other conditions stipulated under cinematograph rules and also laws regarding conversion of land use by the competent authority.
(c) (i) the Semi-permanent cinema site is situated by the side of a public thoroughfare the minimum width of road including footpath should be twelve meters in urban areas and nine meters including footpath in rural areas:
Provided that the Licensing Authority may, by order in writing, subject to such conditions and restrictions may permit, if the cinema or multiplex site is situated by the side of a public thoroughfare other than National Highway/State Highway/Major District Roads the minimum width of road including footpath should be nine meters in urban and rural areas.
(d) The semi-permanent cinema building shall have a front set back of eight meters or as prescribed in the Karnataka Highway Rules, 1966, whichever is higher.
(e) The cinema site has entrance and exit for the public on such roads, the entrance and exit shall have minimum width of six meters each.
(f) The cinema site has suitable parking space, for the theaters existing as on the of commencement of these rules,-
(i) at one car parking space for every fifty seats, subject to a minimum of space for twenty cars in places having a population of ten lakhs and above;
(ii) at one car parking space for every fifty seats, subject to a minimum of space for fifteen cars in places having a population between one to ten lakhs; and
(iii) at one car parking space for every fifty seats, subject to a minimum of space for ten cars in places having a population between Fifty Thousand and one lakh
(iv) at one car parking space for every fifty seats subject to a minimum of space for five cars in places having a population of less than fifty thousand.
(g) The cinema site has suitable parking space, for the theatres proposed as on and from the date of commencement of these rules,-
(i) at one car parking space for every twenty five seats for cinema theatres and one car parking space for every twenty five seats for multiplexes subject to a minimum of space for twenty cars in places having a population of ten lakhs and above;
(ii) at one car parking space for every fifty seats for cinema theatres and one car parking space for every twenty five seats for multiplexes subject to a minimum of space for fifteen cars in places having a population between one to ten lakhs; and
(iii) at one car parking space for every fifty seats for cinema theatres and one car parking space for every twenty five seats for multiplexes subject to a minimum of space for ten cars in places having a population between fifty thousand and one lakh;
(iv) at one car parking space for every fifty seats for cinema theatres and one car parking space for every twenty five seats for multiplexes subject to a minimum of space for five cars in places having a population of less than fifty thousand.
(h) Semi-permanent cinema site existing as on the date of commencement of these rules and the semi-permanent cinema site proposed as on and from the date of commencement of these rules has suitable parking space,-
(i) An additional two and three wheeler parking of twenty five percent of the required number of car parking shall be provided including that for cycle parking subject to a minimum of fifty cycles;
(ii) In case of a Semi-permanent the vehicle parking requirement shall be as prescribed above or as prescribed in the respective zoning regulations, whichever is higher. In such cases, vehicle parking for the theatre portion should be exclusively earmarked in the total parking requirement for the whole building:
Provided that suitable parking arrangements shall be earmarked for physically challenged persons.
(i) The Semi-permanent site is situated at a place where it is not likely to cause traffic difficulties or problem.
(j) The Semi-permanent site is at a distance of not less than,
(a) Fifty meters from.—
(i) any existing petrol bunk or place licensed for a petrol bunk and other places of fire resort; or
(ii) any place of community worship, cremation ground, graveyard or cemetery in use; or
(iii) any recognized educational institution or any residential institution attached to such educational institutions; or
(iv) any public hospital or a private nursing home; or
(v) any recognized orphanage; or
(vi) any thickly populated residential area or an area used generally for residential purposes as distinguished from business purposes:
Provided that the Licensing Authority may, if the proposal is to construct a sound proof cinema building, at its discretion, in public interest, considering the suitability of the place, for reasons to be recorded in writing after inspection of the proposed site, relax, subject to such conditions as it may consider necessary to impose in each case, all or any of the conditions specified in item (i) to (vi):
Provided further that considering the facts and circumstances of each case different conditions may be imposed in different cases.
(b) One hundred meters from any protected monument, defence installations, national parks, museums, and buildings in which main telephone or telegraph or wireless or telecommunication installations are located.
(2) (a) In places having a population of ten thousand or more the number of cinemas to be permitted shall be determined.—
(i) If it is a metropolitan area on the basis of one cinema for every twenty thousand population or a fraction thereof exceeding ten thousand; and
(ii) In other places, on the basis of one cinema for every ten thousand population or a fraction thereof exceeding five thousand;
(b) Location of cinemas shall not be permitted within a distance of four hundred metres from each other in towns and cities having a population of five lakhs and above.
(3) Nothing in sub-rule (2) shall apply for location of cinemas in a metropolitan area if the cinema building is owned by the local authority concerned.
(4)(a) Each ward in a metropolitan area shall for the purpose of Section 6 be an area. The Licensing Authority may having regard to the provisions of Section 5 and the provisions of sub-rule(2) as if each such ward is a place for the purpose of said sub-rule (2) limit the number of places that can be licensed under the Act in each such ward:
Provided that the total number of places so determined in respect of all such wards shall not exceed the number permissible under sub-rule (2) in respect of the metropolitan area taken as a whole.
(b) No order under section 6 shall be made except with the prior approval of the Government.
explanation.___ (1) For the purpose of sub-rules (2), (3) and (4). __ (1) ‘distance’ shall be reckoned along the shortest pathway, lane, street or road connecting the two cinemas and generally used by the members of the public;
(2) ‘Metropolitan area’ means a city or town declared as Metropolitan area under Section 8 of the Code of Criminal Procedure, 1973.
(3) ‘Place’ means, in the case of towns and cities having a population of ten thousand and above, the area coming within the jurisdiction of the local authority concerned and in other cases, an area within the radius of five kilo meters from the centre of the local authority in which the cinema is proposed to be located.
(2) (i) the clear distance between the cinema building and the inner limits of the compound wall is not less than 10 metres at the entrance side and 5 meters at the other sides.
On receipt of the No Objection Certificate, the applicant shall submit an application for approval of the Plan of the building to be constructed on the approved site to the Licensing Authority. Such application shall be accompanied by,-
(i) a copy of the No Objection Certificate granted under rule 118;
(ii) a copy of the approved site plan;
(iii) complete plans, elevation and sections in quadruplicate in original printed on tracing film and also in digital format with four prints of the premises and of all erections and buildings thereon drawn correctly to a scale of not less than 1:100 on prints taken out of any of the standard size tracings and showing clearly,-
(a) All dimensions in millimeters and materials of construction indicating the different materials in distinguishing colours and giving in figures dimensions the width and depth of walls, beams, scantlings and trusses;
(b) The width of all staircases and the number of steps in each flight with the rise and tread of steps the clear width of corridors, passages, openings, aisles and gangways as well as the height and constructions of all galleries, tiers, balconies and stages; and fire resistance rate of staircases shall be one hour. No gas pipeline or electrical lines shall be attached to it. Anti slippery nosing shall be installed for the steps. One meter height of handrail should be provided.
(c) the sizes of all doors, windows and ventilators indicating their construction and the way in which they open and the proposed system of ventilation;
(d) the proposed seating arrangement;
(e) the plinth area of each building in square meters separately for ground floor and upper floors and in tiers, galleries or balconies;
(f) staircases;
(g) water closets and urinals;
(h) levels at the different parts of the building in plans and sections; and
(i) details and positions of projectors, screen, sound box and other plants and equipment;
(iv) On receipt of the acceptance of design and specification by the executive engineer Public works, Ports and inland transport Department, the Licensing Authority shall direct the applicant to submit the plans and electrical drawings in quadruplicate in blue print or computer print and also in digital format showing the location of the cinematograph apparatus and complete electrical installations wiring diagram indicating all wiring, light- points, switches, plugs, distribution boards and other electric machinery indicating different circuits in different colours and earthing details to the Electrical Inspector.
(v) Thereafter, the Electrical Inspector shall examine the designs pertaining to the cinematograph plant, the electrical installations along with electrical wiring diagram and plan details showing the electrical system submitted by the applicant and if he is satisfied after scrutiny, that they are in accordance with the provisions of these rules relating to safety of electrical installation, he shall forward his report to the Licensing Authority within fifteen days.
(vi) Detailed specifications of the works in triplicate to be executed, sufficiently describing the material to be employed and the mode of construction to be adopted with calculations, in triplicate showing the loads coming and stresses occurring in all foundations, piers, columns, stanchions, lintels, beams, slabs, joists and trusses, such calculations being certified to be correct by a graduate engineer or a design engineer or a design practitioner or a qualified architect.
(1) The Licensing Authority shall subject to section 5 and orders, if any, made by him under Section 6, if satisfied that the site fulfills all the conditions specified in rule 26, grant to the applicant a No Objection Certificate in form D for the construction of the semi permanent cinema or cinema building. The Certificate shall be valid for a period of two years from the date of commencement of the construction of the building. The Licensing Authority on an application made to him in this behalf, if satisfied that the applicant could not for valid reasons, complete the building within the said period of two years, may extend the validity of such certificate by a period not exceeding one year at a time so, however, the total period does not exceed three years.
(2) The applicant shall, within twelve months from the date of the certificate, commence construction of the building. The Licensing Authority may, on an application made to it in this behalf, if satisfied that the applicant could not for valid reasons commence construction of the building within the said period, extend the period by a period not exceeding one year. If construction of the building is not commenced within the said period of one year or the extended period of one year if any, the certificate shall, on the expiry of the said period, stand cancelled.
(3) The licensing authority shall consider the application for grant of No Objection Certificate within forty five days from the date of application. If not, the No Objection Certificate shall be deemed to have been granted.
(4) Procedure for approval of subsequent additions and alterations.- (i) The licensee shall give notice in writing to the Licensing Authority of his intention to add or alter the licensed place or any portion thereof. Such notice shall state clearly the additions or alterations proposed and shall be accompanied by complete plans, elevations and sections and block plans and specifications of the work to be executed drawn up in quadruplicate in the manner required by rule 31 along with the original certificates. It shall not be necessary to obtain a No Objection Certificate for this purpose. The Licensing Authority shall before according sanction to the proposed additions or alterations, follow the procedure laid down in sub-rule 1 and 2 of rule 32. The licensing Authority shall after the receipt of opinion under rule 32 approve the proposal of such addition or alterations within fifteen days from the date of receipt of notice.
(ii) Additions and alterations of cinema theatre shall include increasing the number of screens from one to two or three in the existing licensed premises without increasing the area or the total number of seats approved for single screen viewing and all other provisions relating to a permanent cinema theatre in these rules shall be applicable to such additions and alterations of cinema theatre or multiplex.
(5) Procedure for sanction of subsequent additions and alterations to the Electrical Installation.- (i) The licensee shall give notice to the Licensing Authority in writing of his intention to make additions or alterations to the electrical installations or apparatus. The Licensing Authority shall forward such notice to the electrical inspector. Where the electrical inspector reports after inspection that the alterations or additions proposed are in accordance with the provisions of these rules, the Licensing Authority shall approve the proposal following as far as may be, the procedure laid down in sub-rule(3) of rule 32.
(ii) If, in the opinion of the Licensing Authority, further inspection is necessary, he may direct and require the licensee to pay in advance fees specified in this behalf by the Government from time to time.
(iii) If during the interval between two periodical inspections, any further inspection shall in the opinion of the electrical inspector becomes necessary on account of the neglect or failure of the person in charge to carry out any written orders of such officer issued under subrule(2) of rule 4 within the time specified by him or if during any inspection the installation be found defective, fees specified in this behalf by the Government from time to time shall be charged for such further inspection and such fee shall be paid by the licensee.
(1) The licensee shall notify.-
(a) The Executive Engineer, Public works, Ports and inland transport Department of the district, fifteen days earlier to the commencement of construction of cinema or multiplex and ancillary buildings to enable him to issue the certificate of soundness under sub-rule (3); and
(b) The Electrical Inspector of the district, fifteen days earlier to the commencement of wiring for electrical installation, to enable him to issue the electrical certificate under sub-rule (4). Such notice shall be accompanied by a treasury challan for having paid the fees specified under sub-rule (8).
(2) On completion of the building and electrical installation according to the approved plan, the applicant shall obtain after an application being made,-
(a) a certificate from the executive engineer, Public works, Ports and inland transport Department in respect of matters covered in the provisions of rules 43 to 56;
(b) a certificate in form ' E -1' from the Electrical Inspector in respect of matters covered by the provisions of rules 3, 48, 51(9), 57 to 73, 77(5) and 82;
(c) a certificate in form ‘E-2’ from the Fire Officer, Fire and Emergency Services of the district in respect of matters covered under Chapter – IX.
(d) a certificate in form ‘E-3’ from the District Health and Family Welfare Officer in respect of matters covering the provisions relating to health and cleanliness of the premises.
(e) In case of semi-permanent cinema, the licensee shall obtain a separate No Objection Certificate from the Department of Fire and Emergency Services for the whole building including the theatre portion.
(3) If the executive engineer public works, Ports and inland transport department is satisfied about the structural soundness of the cinema or semi-permanent cinema building, he shall issue a certificate within fifteen days after receipt of the application under sub-rule (2) and such certificate shall be valid for period of five years.
Provided that in the case of any semi-permanent cinema which does not fulfill the requirements of the rule the executive engineer public works, Ports and inland transport department may reject the application for issuing of certificate for five years or may reduce the period of the certificate, for reasons to be recorded in writing and after giving the applicant an opportunity of being heard, and the reasons shall be communicated to the Licensing Authority.
(4) Within fifteen days after the receipt of the application under sub-rule(2), Electrical Inspector of the district or area shall, if he is satisfied about the suitability of the electrical installations and equipments, issue a certificate to that effect and such certificate shall be in form ‘E-1’ and shall be valid for a period of five years from the date of issue:
Provided that in the case of any semi-permanent cinema which does not fulfill the requirements of the rule the deputy Electrical Inspector may reject the application for issuing of certificate for five years or reduce the period of the certificate, for reasons to be recorded in writing and after giving the applicant an opportunity of being heard, and the reasons shall communicated to the Licensing Authority.
(5) (a) If the Fire Officer of the Karnataka State Fire and Emergency Services of the district is satisfied that the Fire Fighting appliances and other equipments specified in Chapter IX are provided to the cinema or multiplex building, he shall issue a certificate in form ‘E-2’ to that effect within fifteen days after the receipt of the application, which shall be valid for a period five years:
Provided that in the case of any cinema theatre or multiplex which does not fulfill the requirements of the rule the fire officer may reject the application for issuing of certificate for five years or may reduce the period of the certificate, for reasons to be recorded in writing and after giving the applicant an opportunity of being heard, and the reasons shall be communicated to the Licensing Authority.
(b) Efficiency/Fitness/Working condition of the fire fighting appliances in every cinema theatre or multiplex shall be checked annually by the Fire Officer of the district.
(6) If the District Health & Family Welfare Officer of the district is satisfied about the provisions made for maintenance of sanitary facilities, public health, hygiene and cleanliness of the premises; he shall issue a certificate in form ‘E-3’ to that effect, within fifteen days after receipt of the application, which shall be valid for a period of five years:
Provided that in the case of any cinema theatre or multiplex which does not fulfill the requirements of the rule, the district health and family welfare officer may reject the application for issuing of certificate for five years or may reduce the period of the certificate, for reasons to be recorded in writing and after giving the applicant an opportunity of being heard, and the reasons shall be communicated to the Licensing Authority.
(7) For the purpose of issuing a certificate under sub-rules (3), (4), (5) and (6), the executive engineer public works, Ports and inland transport department, Electrical inspector of the district or area, The fire officer of the district, The District Health and Family Welfare Officer shall visit and inspect the cinema or multiplex building and premises and their inspection reports shall be part of the report submitted to the Licensing Authority.
(8) Fees for inspection and issue of the certificates regarding the cinema theatres and multiplexes shall be as specified by the government from time to time and credited to the head of account so specified.
(9) A copy of the certificate issued by the above offices may be obtained from them on payment of fees notified by the government.
(1) For purposes of this Chapter, unless the context other-wise requires, “Bush” means packing inserted in the holes through which the pipes and cables pass in order to render such holes reasonably smoke proof.
(2) Any word not defined in these rules particularly in this chapter shall have same meaning and expressions as defined in the Electricity Act, 2003 (central Act 36 of 2003) and Central Electricity Authority (Measures relating to Safety and Electric Supply) Regulations
(1) The electric lighting of the premises shall have at least three separate and distinct main circuits and these shall be,-
(a) Circuit ‘A’ for the projection room and then, through dimming regulator if any, to the central lighting of the auditorium,
(b) Circuit ‘B’ for approximately one half of the auditorium, passage ways, stair ways, exits and parts of the buildings open to the public and
(c) Circuit ‘C’ for the remaining half of the auditorium, passage ways, stair ways, exits and parts of the buildings open to the public.
(2) The control of the circuits in respect of ‘B’ and ‘C’ shall be remote from each other.
(1) Where supply is available on three phase AC system, the circuits ‘A’, ‘B’ and ‘C’ shall be supplied from three different phases to balance the load
(2) The main circuits ‘A’ ‘B’ and ‘C’ may be subdivided into as many sub-circuits as may be considered necessary. Each sub-circuit shall start from a distributing board and must be through a suitable capacity Earth leakages circuit breakers (ELCB)
(3) The lights inside and outside the premises shall be separate circuits. Circuits for fans, power and cooling purposes shall be kept distinct and separate from lighting circuits.
(4) Power saving and modern technology lighting system shall be adopted like LED, etc.
(1) In any semi-permanent cinema, arc lamps shall not be used in the auditorium or in any part open to the public without permission from the Electrical Inspector. When they are used in any part of such premises, special precautions shall be taken to guard against danger from falling glass and incandescent particles or carbon. All parts of the lamps, lanterns and fittings which are liable to be handled (except by the person employed to handle them) shall be insulated from the framework.
(2) Any exposed portion of metal work of an arc lamp liable to become heated to a temperature sufficient to cause conflagration by contact with scenery or other inflammable material shall be projected by a wire guard. In no case shall arc lamps be suspended by the conductors.
(3) All arc lamps shall be connected with airtight ducts leading to atmosphere.
(4) Advanced technology projector and sound system like digital projectors, digital sound system and any other type of advanced technology can be installed and used in any part of the Semi-permanent cinema after obtaining permission from the Electrical Inspector of the district or area.
All resistances, with the exception of a resistance for regulating purposes, shall be placed outside the projection room and, if reasonably practicable, outside the auditorium. If placed inside the auditorium, such resistances shall be protected by an earthed wireguard or other efficient means of preventing accidental contacts.
Within the projection room, all electric cables, be of fire retardant low smoke type and all cables shall be enclosed in conduits. All conduits leading to projectors and motors from switch board shall be embedded in the floor finish without cutting the floor slab and in no case the conduits and cables be allowed on floor surface.
Cables for Cinematograph lamps or digital projector shall be taken as separate circuits from the projection room power distribution board. An efficient double pole switch with proper fuse protection shall be fitted within the projection room in the cinematograph lamp circuit.
(1) Foot lights shall be provided in gangways and passages within the auditorium, the voltage of which shall not exceed twentyfour volts.
(2) All lights in the staircases, corridors, passages and exits shall be kept alight during the time the public are in the cinema and they shall be connected to alternate source of power.
(3) At least six torches shall be kept on the premises in proper working order throughout when the public are on the premises and shall be distributed over the building so as to be easily accessible to the door keepers.
(4) Emergency lights covering all the exits shall also be provided.
(5) Emergency sign boards (fire exit, staircase, safe assembly, fire extinguisher, emergency alarm switch etc.,) shall be kept brightly and clearly visible.
(1) The electrical wiring of the entire semi-permanent cinema premises should be done in conduit pipe, metallic or approved rigid poly vinyl chloride.
(2) Bushes shall be used wherever necessary for metallic conduit pipes. All metallic tubing shall be efficiently earthed and shall be provided with screw joints or other means of ensuring a good and permanent electrical connection which must be continued with boxes and other fittings.
(1) All suspended fittings shall be firmly fixed.
(2) Combined gas and electric fittings shall not be used.
(3) Any electric light pendants or brackets in the auditorium and in front of the cinema or multiplex building generally shall be at least two and half metres above the floor to the lowest projecting part of the fittings. No electrical fittings or apparatus of any description shall be so fixed or arranged as to interfere at any time with the proper working of the safety curtain.
(4) (i) The electrical installation shall be incharge of a properly qualified person holding a Wireman’s or Supervisor’s permit issued by the Licensing Advisory and Examination Board of the Government of Karnataka or shall be incharge of a licensed Electrical Contractor whose name shall be intimated to the Electrical Inspector of the district or area.
(ii) Licensed Electrical Contractor shall furnish insulation resistance of all circuits and values of earth electrode annually to Electrical Inspector of the district.
(5) Instructions both in English, Hindi and in regional languages for the restoration of persons suffering from electric shock shall be affixed in a conspicuous place and at least one pair of rubber gloves in good order shall be provided for use of the wiremen.
(6) Earthing shall be done efficiently and perfectly as per Electricity Act 2003, Central Electricity Authority (measures relating to Safety and Electric Supply) Regulation 2010 and rules and regulations thereafter, I S S 3043/1987 and shall be maintained properly. Earth electrodes shall be kept exposed and enclosed in masonry enclosures as per I.S. standards so as to facilitate watering, inspection and periodical testing.
A framed wiring diagram in single line indicating clearly the arrangement of all circuits and sub-circuits of the electrical installation the position of distribution boards and the size of cables shall be displayed in the premises and shall be kept up-to date. Such diagram shall also be maintained in digital format be duly approved by the Electrical Inspector.
After obtaining the certificates referred to in Rule 121 the applicant may submit his application for licence in writing to the Licensing Authority. The application shall be accompanied by,-
(a) the certificate issued by the Executive Engineer Public works, Ports and inland transport Department under sub rule(3) of rule 121;
(b) (i) The certificate issued by the Deputy Electrical Inspector of the district or area under sub rule(4) of rule 121;
(ii) the certificate issued by the Fire Officer of the District under sub rule(5) of rule 121;
(iii) the certificate issued by the District Health and Family Welfare Officer under sub rule(6) of rule 121.
(c) a declaration by the applicant that he has completed all arrangements for obtaining films approved by the Central Government with the previous approval of the Films Division for exhibition at each performance together, with a statement from the suppliers confirming that such arrangements have been made; and
(d) a treasury challan for the payment of licence fees as notified by the Government.
(1) On receipt of the application for license the Licensing Authority shall, if he is satisfied that all works are carried out as per approved plans and all arrangements are made for exhibition of film, issue to the applicant within fifteen days from the date of its receipt a licence in form ‘F’ or refuse to issue such licence for reasons to be recorded in writing. The Licensing Authority may refuse to issue a licence if the application for the license is not made before the expiry of the period of validity of the No Objection Certificate. For this purpose, the Licensing Authority may make such local inspection as he considers necessary. A copy of the plans and drawings referred to in rule 33 shall be attached to the license.
(2) A copy of the licence may be obtained from the Licensing Authority on payment of fees notified by Government from time to time.
Semi permanent cinema theatres may be granted exhibition licence for five years but not less than three years subject to annual clearance from Fire and Emergency Services and Electrical Inspectorate Department at a time at the end of which the building shall be inspected in detail by the Executive Engineer, Public Works, Ports and inland transport Department of the district as also the Electrical Inspector of the district who shall furnish a certificate as to the ‘soundness’ of the building for being licensed for a period beyond five years. A licence granted under rule 140 shall not be regranted beyond a period of thirty years from the date of first grant of such licence. Unless, If before the expiry of the said period of thirty years the applicant converts the building into a permanent theatre or modifies or alters it in to two or more screens, as per existing provisions of these rules necessary licence under rule 121(7) shall be granted if the required conditions are satisfied.
The front portion of the premises shall be masonry construction of sufficient height and the remaining portion may be a compound wall/ barbed wire fencing or any other locally available suitable material so as to prevent outside public from causing any inconvenience to the persons within the premises.
For construction of semi-permanent cinema buildings, as far as possible, building materials locally available such as Stone, Brick, Cement / Lime or Jungle wood, Zinc sheet /A.C. sheets, block board, impregnated in bituman (asphaltic sheets) for roof etc., may be used. Doors and windows may be of steel or jungle wood. The external walls may be of either brick in Cement / Lime and the height of walls shall be not less than 2.6 metres.
(1) The cinematograph apparatus shall be placed in a room of substantial construction made of fire proof materials of 2-4 hour ratings, the floor of which shall have a minimum floor finish of fifty milimetres to embed cables under rule 132:
Provided that in the case of existing and proposed semi-permanent cinema theatres with advanced technology like digital projectors, digital sound system, a separate projection room is not mandatory.
(2) The projection room shall have no connection with the auditorium, except the projection and observer openings:
Provided that in the case of existing and proposed semi-permanent cinema theatres with advanced technology like digital projectors, digital sound system, a separate projection room is not mandatory.
(3) The projection room having one projector must have at least seven and half square meters floor area with 2.5 meters as smallest dimension and with a clear height of not less than 3 meters. For each additional projector, there shall be 2.3 square meters of floor space:
Provided that in the case of existing and proposed cinema theatres or multiplex with advanced technology like digital projectors, digital sound system, a separate projection room is not mandatory.
(4) There shall be a regular staircase leading to ground floor and to floor below.
(5) The door of the projection room shall be fire-proof and all openings, bushes and joints shall be so constructed and maintained as to prevent, as far as possible, the escape of any smoke into the auditorium. Ventilation shall be provided for the projection room, but the ventilation ducts shall not communicate direct with the auditorium. The area of the ventilating ducts shall not be less than one per cent of the floor area of the projection room.
explanation.- In this rule, bush means packing inserted in the holes through which the pipes and cables pass in order to render such holes reasonably smoke proof.
Provided that in the case of existing and proposed cinema theatres or multiplex with advanced technology like digital projectors, digital sound system, a separate projection room is not mandatory.
(6) There shall be a rewinding room or enclosure by the side of the projection room for the purpose of rewinding of films and where the rewinding room or enclosure adjoins the projection room and has door in between, leading from one to the other, this door shall be self closing fire resistant door:
Provided that in the case of multiplex or a existing and proposed cinema theatre with advanced technology like digital projectors, digital sound system, a separate rewinding room is not mandatory.
(1) There shall be sufficient ventilators for each room or passage in every semi-permanent cinema with an area of not less than one-eighth of the floor area, twothirds of which shall be so arranged as to be kept open during performances. There shall also be sufficient means of artificial ventilation with the help of not less than one ceiling fan for every fifty seats and one exhaust fan for every fifty square meters of the auditorium, which shall be approved by the Executive Engineer, Public Works, Ports and inland transport Department.
(2) Alternatively, there shall be suitable centralized ventilation system of sufficient capacity, which shall be approved by the Executive Engineer, Public Works, Ports and inland transport Department.
(3) There shall be sufficient ventilation system for the auditorium of air conditioned semi-permanent cinema or air cooled semi-permanent cinema theatres which shall be approved by the Executive Engineer, Public Works, Ports and inland transport Department:
Provided that when the ventilation system fails during the performance, the show shall be stopped during the period of its failure.
(7) If the enclosure is inside the auditorium, no openings other than those required for projection and observation of the enclosure shall be permitted to communicate with the auditorium. The rewinding room or enclosure by the side / inside the projection room for the purpose of rewinding rooms shall have a self closing fire resistant door:
Provided that in the case of multiplex or a existing and proposed cinema theatre with advanced technology like digital projectors, digital sound system, rewinding room is not mandatory.
(8) The projector openings shall be in accordance with the type of projection such as 35 millimeters, 70 millimeters, Cinemascope and Cinerama, Wide angle, Vista vision:
Provided that in the case of multiplex or a existing or proposed cinema theatre with advanced technology like digital projectors, digital sound system, then this sub rule shall not apply.
(9) Each Opening shall be provided with a plate glass screen of not less than 5 millimeters, in thickness fixed in position with a smoke tight joint:
Provided that for openings for more than 250 millimeters square,-
(a) The glass screens used shall be armored plate or wired plate glass;
(b) The metal screens shall be provided in addition to the glass screens and the openings shall be closed with the metal screens when not in use for projection; and
(c) a notice shall be put in the cabin to the effect that the openings shall be closed with the metal screens when the openings are not in use.
(10) (i)Projection room shall be in the charge of a person who has attained the age of 18 years and who is holding a Cinema operator’s permit issued by the Chief Electrical Inspector to Government.
Provided that, a candidate who holds a certificate for having passed the Craft Course in Cinema operation or Diploma in Cinematography conducted by the Board of Technical Education in Cinematography in Karnataka or degree/diploma in Electrical and Electronics Engineering recognized by the State Government or Central Government shall be exempted from appearing for the examination conducted by the Karnataka Cinema Operator’s Examination Board for obtaining the cinema operator permit.
(ii) The operator shall satisfy himself before the commencement of each performance that all cables, leads, connections and resistances as also the portable fire extinguishers in the projection room are in proper working order. He shall be present in the projection room during the time the machine is being operated:
(iii)Provided that in the case of multiplex or existing or proposed cinema theatre with advanced technology like digital projector, digital sound system, although projection room is not mandatory the operator shall be present during the time the machine is being operated.
(iv) Failure to employ such an operator shall render the electrical certificate of cinema theatre or multiplex liable to be suspended or cancelled.
(11) Two operators shall be got endorsed in favour of the theatre with conventional projectors and one operator per screen shall be got endorsed in favour of the theatre with advance technology like digital projection system, from the Department of Electrical Inspectorate.