(1) The standard size of the hoarding boards shall be as follows:-
| S1.No. | Description of Advertisement | Specific parameters | |||
| Commercial Billboards erected on Roof-top / Ground. | Max Length (Horizontal) in Meter | Max Width (Vertical) in Meter | Max Height from base of structure in Meter | Min Ground Clearance in Meter | |
| 1 | For ROW less than 30M, width. (roof top/wall mounted) | 12 | 6 | 18 | NA |
| 2 | For Row more than 30M, width. (roof top / wall mounted) | 18 | 9 | 18 | NA |
| 3 | Trivision | 12 | 6 | 18 | NA |
| 4 | Variable message Advertising devices such as LED, LCD Screens etc. | 12 | 6 | 2.5 if on Ground.NA if on Roof. | |
| 5 | Billboards erected on Ground | 18 | 9 | 25 | 2.5 |
| Commercial Billboards may also be put up against Building Walls, the Criteria shall be similar to a Roof Top erection. | |||||
(3) No hoarding shall be erected to a height exceeding 25meters above the road level. The lower base or the bottom of hoarding shall be a height not less than 2.5meters from the surface below.
The maximum height of the hoarding erected on the terrace of a building shall not be more than 12.2 meters from the terrace level.
(5) A minimum distance of 1.50 meters shall be maintained beyond the edge of the ROW.
(6) The lower bottom of the hoarding board shall not be at a height less than 3.05 meters (10 ft).
(7) The advertisement along roads shall not be permitted within a distance of 25 meters from the stop line of the approach road or junctions.
(8) Sandwich (back to back) and (‘V’ shape) hoarding having standard size can be permitted.
(9) The structural framework supporting advertisement board shall not be outsized compared, to the permitted board size and shall be within tolerance limits on either side laterally. No vertical tolerance is permitted except the columns up to the ground clearance. Any incremental deviation shall be deemed to be an increase in the size of the advertisement board against norms and breach of the terms and conditions of the permit.
(10) Existing Legacy Advertisement Bill boards which were permitted prior to these rules shall be given a grace period of upto6 (six) months to obtain permission under these rules. Upto 6 (six) months from the date of the permission shall be given to set right the size, height and ground clearance as per the rules. However, display of advertisements on Legacy Advertisement Bill boards not conforming to size, height and ground clearance as specified under these rules shall not be allowed in the grace period or thereafter.
(11) Construction fence may be allowed as no lit special advertising structure, temporary in nature, which will be non-standard advertising field, subject to height restriction of 10ft. from the ground.
(12) Kiosks advertisement displaying on electric point etc., shall be a standard size of 2.5’ x 3.25’ height all over the city and bottom clearance of 10ft. from the ground.
(13) Advertisements on public infrastructure through PPP:
(a) Specific public infrastructure financed by private business, philanthropies, or individuals. Sponsoring individual, institution, is permitted to display a memorial plaque containing name, date, public message. The PPP concession may expressly be in terms of the advertisement rights for:
i. Bus Shelter a. Commercial signage sponsorship is permitted for bus shelters, not more than one bus shelter unit per 300 meters on the same side of Right-of-way.
b. Permit validity is to be determined by the Authority, based on “Value for Money” analysis.
c. Advertisement to be not more than 2.5 meters height from ground up.
d. Not extending outside the roof of the bus stop.
e. Total surface coverage not more than seventy percent of the interior vertical surface of the shelter.
ii. - The size should be limited to not more than 50% of exterior vertical surface of the bridge/ skywalk across the road without affecting natural lighting & ventilation.
iii. –The size should be limited to not more than 25% of exterior vertical surface of the Public Toilets including e-Toilets. Additional pole or hoarding display whether illuminated or non-illuminated shall not be allowed.
iv. Electric Vehicle Charging Stations, Traffic May be individually reviewed by the Review Committee and additional relevant Authorities to ensure design and message enhances the environment. However the size should be limited to not more than 25% of exterior vertical surface of the structure.
(b) In case of PPP projects, other than the size of the advertisement allowed in above sub rule (a), any additional pole, hoarding or any other type of display whether illuminated or non-illuminated shall not be allowed under any circumstance.